HL7 Component Table - OG - Observation Grouper
Core Framework | Base Standard Profile | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Seq# | Description | Interpretation | Flags | Cardinality | Length | C.LEN | Vocabulary | Data Type | Implement | Cardinality | Vocabulary |
OG | |||||||||||
1 | Original Sub-Identifier | [0..1] | ST | ||||||||
2 | Group | [0..1] | NM | ||||||||
3 | Sequence | [0..1] | NM | ||||||||
4 | Identifier | [0..1] | ST |
Definition: The components that can be used to define the structure of the observation/result segments (OBX) within an observation report segment (OBR).
Example: Original Mode - |1.3 2| where the dot and space are locally defined; Enhanced Mode - |^1^3^2| where the standard defines the purpose of the components to enable grouping.
Definition: The Original Sub-Identifier component represents the original data type used in OBX-4 to enable backwards compatibility to continue use of the original format to provide OBX segment grouping.
Definition: The Group component indicates the group and its sequence within the OBR segment that the OBX segment is a part of.
Definition: The Sequence component indicates the sequence within the group as defined in OG-2.
Definition: The Identifier component enables assignment of an identifier to a result component, for example an isolate in a microbiology message. Futher guidance on how to use this field will be found in an Implementation Guide.