visit the hl7 website The Demo site for our new HL7 Version 2+ (plus) Standard

18.8.86 NDS - Notification Detail Segment (13.4.7)

The equipment notification detail segment is the data necessary to maintain an adequate audit trail as well as notifications of events, (e.g., alarms that have occurred on a particular piece of equipment.

HL7 Attribute Table - NDS - Notification Detail

Base Framework
Seq#Data ElementDescriptionFlagsImplementCardinalityLengthC.LENVocabularyData Type
NDS
101398Notification Reference Number
=

Truncation not allowed!

SHOULD[1..1] 10
NM

Numeric

201399Notification Date/Time SHOULD[1..1] 
DTM

Date/Time

301400Notification Alert Severity SHOULD[1..1] univ: AlertLevel (CD)
CWE

Coded with Exceptions

401401Notification Code SHOULD[1..1] NotificationCode (CD)
CWE

Coded with Exceptions

Seq#Data ElementDescriptionFlagsImplementCardinalityLengthC.LENVocabularyData Type
NDS
101398Notification Reference Number
=

Truncation not allowed!

SHALL[1..1] 10
NM

Numeric

201399Notification Date/Time SHALL[1..1] 
DTM

Date/Time

301400Notification Alert Severity SHALL[1..1] univ: AlertLevel (CD) hl7VS-alertLevel (VS) alertLevel (CS)
CWE

Coded with Exceptions

401401Notification Code SHALL[1..1] NotificationCode (CD)
CWE

Coded with Exceptions

Base FrameworkBase Standard Profile
Seq#Data ElementDescriptionFlagsImplementCardinalityLengthC.LENVocabularyData TypeImplementVocabulary
NDS 
101398Notification Reference Number
=

Truncation not allowed!

SHOULD[1..1] 10
NM

Numeric

SHALL
201399Notification Date/Time SHOULD[1..1] 
DTM

Date/Time

SHALL
301400Notification Alert Severity SHOULD[1..1] univ: AlertLevel (CD)
CWE

Coded with Exceptions

SHALLhl7VS-alertLevel (VS) alertLevel (CS)
401401Notification Code SHOULD[1..1] NotificationCode (CD)
CWE

Coded with Exceptions

SHALL
Base Framework Base Standard Profile
Seq# Data Element Description Flags Optionality Repetition Length C.LEN Table Data Type Optionality Table
NDS  
1 01398 Notification Reference Number   O     10=  
NM

Numeric

R  
2 01399 Notification Date/Time   O      
DTM

Date/Time

R  
3 01400 Notification Alert Severity   O     (0367)
CWE

Coded with Exceptions

R  
4 01401 Notification Code   O     (0610)
CWE

Coded with Exceptions

R  
Seq# Data Element Description Optionality Repetition Length C.LEN Table Data Type
NDS
1 01398 Notification Reference Number R     10=  
NM

Numeric

2 01399 Notification Date/Time R      
DTM

Date/Time

3 01400 Notification Alert Severity R     (0367)
CWE

Coded with Exceptions

4 01401 Notification Code R     (0610)
CWE

Coded with Exceptions

18.8.86.1 NDS Field Definitions (13.4.7.0)

18.8.86.2 NDS-1 Notification Reference Number (NM) 01398 (13.4.7.1)

Definition: This field contains a unique sequential reference number that may be used by various components to refer to this transaction. This number is generated by the originator of this notification.

18.8.86.3 NDS-2 Notification Date/Time (DTM) 01399 (13.4.7.2)

Definition: This field is the date/time of the notifications.

18.8.86.4 NDS-3 Notification Alert Severity (CWE) 01400 (13.4.7.3)

Definition: The severity of the specific notification. Refer to HL7 Table 0367 - Alert Level in Chapter 2C, Code Tables, for valid entries.

18.8.86.5 NDS-4 Notification Code (CWE) 01401 (13.4.7.4)

Definition: This field contains information about the type of notification being sent. These are manufacturer and equipment specific error or status codes, e.g., AQN0123 - aliquoting error - clot detected. Refer to Table 0610 - Notification Code in Chapter 2C for valid values.