18.8.103 OM4 - Observations That Require Specimens Segment (8.8.12)

The Technical Steward for the OM4 segment is Orders and Observations.

This segment applies to observations/batteries that require a specimen for their performance. When an observation or battery requires multiple specimens for their performance (e.g., creatinine clearance requires a 24-hour urine specimen and a serum specimen), multiple segments may be included, one for each specimen type.

OM4 is a repeating segment. It allows multiple specimens per Order Code and accommodates for multiple alternate specimen for each preferred specimen. In some cases an Order Code can require multiple specimens. In many cases there are preferred specimens and for each preferred it is possible to have one or more alternative specimens. The alternative specimen will carry in OM4-17 the Sequence Number - Test/Observation Master File (OM4-1) of the preferred specimen.

If multiple kinds of specimen are associated with this observation (as in the case for a creatinine clearance), multiple segments may be included, one for each specimen type.

This segment will also allow for reporting Preferred and Alternate specimens, when applicable.

HL7 Attribute Table - OM4 - Observations that Require Specimens

Base Framework
Seq#Data ElementDescriptionFlagsImplementCardinalityLengthC.LENVocabularyData Type
OM4
100586Sequence Number - Test/Observation Master File
=

Truncation not allowed!

MAY[0..1] 4
NM

Numeric

200642Derived Specimen MAY[0..1][1..1]univ: DerivedSpecimen (CD) hl7VS-derivedSpecimen (VS) derivedSpecimen (CS)
ID

Coded Value for HL7 Defined Tables

300643Container Description
=

Truncation not allowed!

MAY[0..*][1..60]60
TX

Text Data

400644Container Volume
=

Truncation allowed.

MAY[0..*] 10
NM

Numeric

500645Container Units MAY[0..*] ContainerUnits (CD)
CWE

Coded with Exceptions

600646Specimen MAY[0..1] Specimen (CD)
CWE

Coded with Exceptions

700647Additive MAY[0..1] univ: Additive/Preservative (CD)
CWE

Coded with Exceptions

800648Preparation MAY[0..1] 
TX

Text Data

900649Special Handling Requirements MAY[0..1] 
TX

Text Data

1000650Normal Collection Volume MAY[0..1] 
CQ

Composite Quantity with Units

1100651Minimum Collection Volume MAY[0..1] 
CQ

Composite Quantity with Units

1200652Specimen Requirements MAY[0..1] 
TX

Text Data

1300653Specimen Priorities MAY[0..*][1..1]univ: Priority (CD) hl7VS-priority (VS) priority (CS)
ID

Coded Value for HL7 Defined Tables

1400654Specimen Retention Time MAY[0..1] 
CQ

Composite Quantity with Units

1501908Specimen Handling Code  MAY[0..*] repr: SpecialHandlingCode (CD)
CWE

Coded with Exceptions

1603311Specimen Preference MAY[0..1] univ: PreferredSpecimen_AttributeStatus (CD) hl7VS-preferredSpecimen-AttributeStatus (VS) preferredSpecimen-AttributeStatus (CS)
ID

Coded Value for HL7 Defined Tables

1703312Preferred Specimen/Attribture Sequence ID MAY[0..1] 
NM

Numeric

1801539Taxonomic Classification Code MAY[0..*] 
CWE

Coded with Exceptions

Seq#Data ElementDescriptionFlagsImplementCardinalityLengthC.LENVocabularyData Type
OM4
100586Sequence Number - Test/Observation Master File
=

Truncation not allowed!

MAY[0..1] 4
NM

Numeric

200642Derived Specimen MAY[0..1][1..1]univ: DerivedSpecimen (CD) hl7VS-derivedSpecimen (VS) derivedSpecimen (CS)
ID

Coded Value for HL7 Defined Tables

300643Container Description
=

Truncation not allowed!

MAY[0..*][1..60]60
TX

Text Data

400644Container Volume
=

Truncation allowed.

MAY[0..*] 10
NM

Numeric

500645Container Units MAY[0..*] ContainerUnits (CD)
CWE

Coded with Exceptions

600646Specimen MAY[0..1] Specimen (CD)
CWE

Coded with Exceptions

700647Additive MAY[0..1] univ: Additive/Preservative (CD) hl7VS-additivePreservative (VS) additivePreservative (CS)
CWE

Coded with Exceptions

800648Preparation MAY[0..1] 
TX

Text Data

900649Special Handling Requirements MAY[0..1] 
TX

Text Data

1000650Normal Collection Volume MAY[0..1] 
CQ

Composite Quantity with Units

1100651Minimum Collection Volume MAY[0..1] 
CQ

Composite Quantity with Units

1200652Specimen Requirements MAY[0..1] 
TX

Text Data

1300653Specimen Priorities MAY[0..*][1..1]univ: Priority (CD) hl7VS-priority (VS) priority (CS)
ID

Coded Value for HL7 Defined Tables

1400654Specimen Retention Time MAY[0..1] 
CQ

Composite Quantity with Units

1501908Specimen Handling Code  MAY[0..*] repr: SpecialHandlingCode (CD) hl7VS-specialHandlingConsiderations (VS) specialHandling (CS)
CWE

Coded with Exceptions

1603311Specimen Preference MAY[0..1] univ: PreferredSpecimen_AttributeStatus (CD) hl7VS-preferredSpecimen-AttributeStatus (VS) preferredSpecimen-AttributeStatus (CS)
ID

Coded Value for HL7 Defined Tables

1703312Preferred Specimen/Attribture Sequence ID MAY[0..1] 
NM

Numeric

1801539Taxonomic Classification Code MAY[0..*] 
CWE

Coded with Exceptions

Base FrameworkBase Standard Profile
Seq#Data ElementDescriptionFlagsImplementCardinalityLengthC.LENVocabularyData TypeImplementVocabulary
OM4 
100586Sequence Number - Test/Observation Master File
=

Truncation not allowed!

MAY[0..1] 4
NM

Numeric

MAY
200642Derived Specimen MAY[0..1][1..1]univ: DerivedSpecimen (CD) hl7VS-derivedSpecimen (VS) derivedSpecimen (CS)
ID

Coded Value for HL7 Defined Tables

MAY 
300643Container Description
=

Truncation not allowed!

MAY[0..*][1..60]60
TX

Text Data

MAY
400644Container Volume
=

Truncation allowed.

MAY[0..*] 10
NM

Numeric

MAY
500645Container Units MAY[0..*] ContainerUnits (CD)
CWE

Coded with Exceptions

MAY
600646Specimen MAY[0..1] Specimen (CD)
CWE

Coded with Exceptions

MAY
700647Additive MAY[0..1] univ: Additive/Preservative (CD)
CWE

Coded with Exceptions

MAYhl7VS-additivePreservative (VS) additivePreservative (CS)
800648Preparation MAY[0..1] 
TX

Text Data

MAY
900649Special Handling Requirements MAY[0..1] 
TX

Text Data

MAY
1000650Normal Collection Volume MAY[0..1] 
CQ

Composite Quantity with Units

MAY
1100651Minimum Collection Volume MAY[0..1] 
CQ

Composite Quantity with Units

MAY
1200652Specimen Requirements MAY[0..1] 
TX

Text Data

MAY
1300653Specimen Priorities MAY[0..*][1..1]univ: Priority (CD) hl7VS-priority (VS) priority (CS)
ID

Coded Value for HL7 Defined Tables

MAY 
1400654Specimen Retention Time MAY[0..1] 
CQ

Composite Quantity with Units

MAY
1501908Specimen Handling Code  MAY[0..*] repr: SpecialHandlingCode (CD)
CWE

Coded with Exceptions

MAYhl7VS-specialHandlingConsiderations (VS) specialHandling (CS)
1603311Specimen Preference MAY[0..1] univ: PreferredSpecimen_AttributeStatus (CD) hl7VS-preferredSpecimen-AttributeStatus (VS) preferredSpecimen-AttributeStatus (CS)
ID

Coded Value for HL7 Defined Tables

MAY 
1703312Preferred Specimen/Attribture Sequence ID MAY[0..1] 
NM

Numeric

MAY
1801539Taxonomic Classification Code MAY[0..*] 
CWE

Coded with Exceptions

MAY
Base Framework Base Standard Profile
Seq# Data Element Description Flags Optionality Repetition Length C.LEN Table Data Type Optionality Table
OM4  
1 00586 Sequence Number - Test/Observation Master File   O     4=  
NM

Numeric

   
2 00642 Derived Specimen   O   [1..1]  
ID

Coded Value for HL7 Defined Tables

  (0170)
3 00643 Container Description   O Y [1..60] 60=  
TX

Text Data

   
4 00644 Container Volume   O Y   10#  
NM

Numeric

   
5 00645 Container Units   O Y    
CWE

Coded with Exceptions

  (0658)
6 00646 Specimen   O      
CWE

Coded with Exceptions

  (0660)
7 00647 Additive   O      
CWE

Coded with Exceptions

  (0371)
8 00648 Preparation   O      
TX

Text Data

   
9 00649 Special Handling Requirements   O      
TX

Text Data

   
10 00650 Normal Collection Volume   O      
CQ

Composite Quantity with Units

   
11 00651 Minimum Collection Volume   O      
CQ

Composite Quantity with Units

   
12 00652 Specimen Requirements   O      
TX

Text Data

   
13 00653 Specimen Priorities   O Y [1..1]  
ID

Coded Value for HL7 Defined Tables

  (0027)
14 00654 Specimen Retention Time   O      
CQ

Composite Quantity with Units

   
15 01908 Specimen Handling Code   O Y    
CWE

Coded with Exceptions

  (0376)
16 03311 Specimen Preference   O      
ID

Coded Value for HL7 Defined Tables

  (0920)
17 03312 Preferred Specimen/Attribture Sequence ID   O      
NM

Numeric

   
18 01539 Taxonomic Classification Code   O Y    
CWE

Coded with Exceptions

   
Seq# Data Element Description Optionality Repetition Length C.LEN Table Data Type
OM4
1 00586 Sequence Number - Test/Observation Master File O     4=  
NM

Numeric

2 00642 Derived Specimen O   [1..1] (0170)
ID

Coded Value for HL7 Defined Tables

3 00643 Container Description O Y [1..60] 60=  
TX

Text Data

4 00644 Container Volume O Y   10#  
NM

Numeric

5 00645 Container Units O Y   (0658)
CWE

Coded with Exceptions

6 00646 Specimen O     (0660)
CWE

Coded with Exceptions

7 00647 Additive O     (0371)
CWE

Coded with Exceptions

8 00648 Preparation O      
TX

Text Data

9 00649 Special Handling Requirements O      
TX

Text Data

10 00650 Normal Collection Volume O      
CQ

Composite Quantity with Units

11 00651 Minimum Collection Volume O      
CQ

Composite Quantity with Units

12 00652 Specimen Requirements O      
TX

Text Data

13 00653 Specimen Priorities O Y [1..1] (0027)
ID

Coded Value for HL7 Defined Tables

14 00654 Specimen Retention Time O      
CQ

Composite Quantity with Units

15 01908 Specimen Handling Code O Y   (0376)
CWE

Coded with Exceptions

16 03311 Specimen Preference O     (0920)
ID

Coded Value for HL7 Defined Tables

17 03312 Preferred Specimen/Attribture Sequence ID O      
NM

Numeric

18 01539 Taxonomic Classification Code O Y    
CWE

Coded with Exceptions

18.8.103.1 OM4 Field Definitions (8.8.12.0)

18.8.103.2 OM4-1 Sequence Number - Test/Observation Master File (NM) 00586 (8.8.12.1)

Definition: The OM4-1 contains a numeric value that indicates a unique set of OM1, OM2, OM3, and OM4 components; each OMn-1 in a set will have the same value as illustrated in the example below. Because the OM4 segment can repeat, but needs to have a unique number for use with OM4-17, the sequence number must be appended with a sequence number as shown in the second example below.

OM4-1 Sequence Number - Test/Observation Master File Example:

MSH|...

// start MFE Test Begin group

MFE|A|...

OM1|1|...

OM2|1|...

OM3|1|...

OM4|1|...

// end MFE Test Begin group

// start MFE_Test_Begin group

MFE|A|...

OM1|2|...

OM2|2|...

OM3|2|...

OM4|2.1|...

OM4|2.2|...

//end MFE_Test_Begin group

18.8.103.3 OM4-2 Derived Specimen (ID) 00642 (8.8.12.2)

Definition: This field contains the codes that identify the parents and children for diagnostic studies—especially in microbiology—where the initial specimen (e.g., blood) is processed to produce results (e.g., the identity of the bacteria grown out of the culture). The process also produces new "specimens" (e.g., pure culture of staphylococcus, and E. coli), and these are studied by a second order process (bacterial sensitivities). The parents (e.g., blood culture) and children (e.g., penicillin MIC) are identified in such cases. Refer to HL7 Table 0170 - Derived Specimen in Chapter 2C, Code Tables, for valid values:

18.8.103.4 OM4-3 Container Description (TX) 00643 (8.8.12.3)

Definition: This field contains the physical appearance, including color of tube tops, shape, and material composition (e.g., red-top glass tube). Note that the color is not necessarily a unique identifier of the additive and/or use of the tube. This is especially true for black and some blue tube tops, as can be seen above. Color is included here for user convenience. This field repeats to accommodate all the possible specimen that will be allowed. If a container is preferred, only that container should be messaged here with the alternate containers messaged in a repeat OM4 segment.

18.8.103.5 OM4-4 Container Volume (NM) 00644 (8.8.12.4)

Definition: This field indicates the capacity of the container. This field repeats to accommodate all the possible specimen that will be allowed. If a container is preferred, only that container should be messaged here with the alternate containers messaged in a repeat OM4 segment

18.8.103.6 OM4-5 Container Units (CWE) 00645 (8.8.12.5)

Definition: This field contains the units of measure of the container volume. If the units are ISO+ units, they should be recorded as single case abbreviations. If the units are ANS+ or L (local), the units and the source code table must be recorded, except that in this case, component delimiters should be replaced by subcomponent delimiters. For example, 1 indicates liters, whereas pt&&ANS+ indicates pints (ANSI units). The default unit is milliliters (ml), which should be assumed if no units are reported. This field repeats to accommodate all the possible specimen that will be allowed. If a container is preferred, only that container units should be messaged here with the alternate containers messaged in a repeat OM4 segment. Refer to Table 0658 - Container Units in Chapter 2C for valid values.

18.8.103.7 OM4-6 Specimen (CWE) 00646 (8.8.12.6)

Definition: Describes the specimen from an appropriate controlled vocabulary. If multiple kinds of specimen are associated with this observation (as in the case for a creatinine clearance), multiple segments may be included, one for each specimen type. Refer to Table 0660 - Specimen in Chapter 2C for valid values.

18.8.103.8 OM4-7 Additive (CWE) 00647 (8.8.12.7)

Definition: This field contains the codes that should be those provided by NCCLS. Refer to HL7 Table 0371 - Additive/Preservative in Chapter 2C, Code Tables, for valid values. The table's values are taken from NCCLS AUTO4. The value set can be extended with user specific values.

This table was not specified in previous versions and thus sites may choose to use other site-specific tables.

18.8.103.9 OM4-8 Preparation (TX) 00648 (8.8.12.8)

Definition: This field contains the special processing that should be applied to the container, e.g., add acidifying tablets before sending.

18.8.103.10 OM4-9 Special Handling Requirements (TX) 00649 (8.8.12.9)

Definition: This field contains the special handling requirements here (e.g., ice specimen, deliver within two hours of obtaining).

18.8.103.11 OM4-10 Normal Collection Volume (CQ) 00650 (8.8.12.10)

Definition: This field contains the normal specimen volume required by the lab. This is the amount used by the normal methods and provides enough specimens to repeat the procedure at least once if needed. The default unit is milliliters (ml).

18.8.103.12 OM4-11 Minimum Collection Volume (CQ) 00651 (8.8.12.11)

Definition: This field contains the amount of specimen needed by the most specimen sparing method (e.g., using micro techniques). The minimum amount allows for only one determination. The default unit is milliliters (ml).

18.8.103.13 OM4-12 Specimen Requirements (TX) 00652 (8.8.12.12)

Definition: This field contains the other requirements for specimen delivery and special handling (e.g., delivery within one hour, iced).

18.8.103.14 OM4-13 Specimen Priorities (ID) 00653 (8.8.12.13)

Definition: This field contains the allowed priorities for obtaining the specimen. Note that they may be different from the processing priorities given in OM1-25 - Processing Priority. When a test is requested, the specimen priority given in TQ1-9 - Priority should be one of the priorities listed here. Multiple priorities are separated by repeat delimiters. Refer to HL7 Table 0027 - Priority in Chapter 2C, Code Tables, for valid values.

18.8.103.15 OM4-14 Specimen Retention Time (CQ) 00654 (8.8.12.14)

Definition: This field contains the usual time that a specimen for this observation is retained after the observation is completed, for the purpose of additional testing. The first component is the duration, and the second component is an ISO time unit.

18.8.103.16 OM4-15 Specimen Handling Code (CWE) 01908 (8.8.12.15)

Definition: This describes how the specimen and/or container need to be handled from the time of collection through the initiation of testing. As this field is not required, no assumptions can be made as to meaning when this field is not populated.

Refer to User-defined Table 0376 - Special Handling Code in Chapter 2C, Code Tables, for suggested values.

18.8.103.17 OM4-16 Specimen Preference (ID) 03311 (8.8.12.16)

Definition: This field indicates whether the Specimen/Attribute is Preferred or alternate for collection of the specimen. There can only be one occurrence of a Preferred or Alternate Specimen/Attribute for the code referenced in OM4-6 Specimen. For example, if two OM4 segments are received for specimen type of Serum, only one can be marked as Preferred. Refer to HL7 Table 0920 - Preferred Specimen/Attribute Status in Chapter 2C, Code Tables, for suggested values.

18.8.103.18 OM4-17 Preferred Specimen/Attribute Sequence (NM) 03312 (8.8.12.17)

Definition: This field contains the value of the sequence number of the Preferred Specimen that these specimens are the alternative for. Note: For the preferred specimen (i.e., OM4-16 = "P"), this field is not populated. This field is used by the Alternate Specimen (i.e., OM4-16 = "A") to point to the preferred specimen that it is to replace or be used as an alternative.

Example:

Preferred specimen

OM4|1||Tiger Top|… to field16|P||

OM4|2||Plastic Screw Top|0.5|mL|Urine|without 6N HCI| … to field16|P||

Alternate specimen

OM4|3||Red Top|… to field16|A|1|

18.8.103.19 OM4-18 Taxonomic Classification Code (CWE) 01539 (8.8.12.18)

Definition: The species of living organism. This may include the common or scientific name, based on the coding system(s) used. SNOMED is the recommended coding system. If this field is not valued, a human is assumed. Refer to User-defined Table 0446 - Species Code for suggested values. Refer to Table 0661 - Taxonomic Classification Code in Chapter 2C for valid values.

For example:

...|L-80700^Canine, NOS^SNM3|...

...|L-80100^Bovine^SNM3|...

...|L-80A00^Feline^SNM3|....

This field is a list of species or other taxonomic classification(s) to which the indicated specimen type may appropriately be applied for the indicated observation or test. If this field is omitted the default meaning is that the test or observation is applicable to humans. In a veterinary context, if the test is applicable to any species, an appropriate code such as "Kingdom Animalia (organism)" should be used to avoid confusion with the meaning of human only.