This segment carries information on a patient's death and possible autopsy.
HL7 Attribute Table - PDA - Patient Death and Autopsy
Base Framework | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Seq# | Data Element | Description | Flags | Implement | Cardinality | Length | C.LEN | Vocabulary | Data Type | |
PDA | ||||||||||
1 | 01574 | Death Cause Code | MAY | [0..*] | CWE Coded with Exceptions | |||||
2 | 01575 | Death Location | MAY | [0..1] | PL Person Location | |||||
3 | 01576 | Death Certified Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | |||
4 | 01577 | Death Certificate Signed Date/Time | MAY | [0..1] | DTM Date/Time | |||||
5 | 01578 | Death Certified By | MAY | [0..1] | XCN Extended Composite ID Number and Name for Persons | |||||
6 | 01579 | Autopsy Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | |||
7 | 01580 | Autopsy Start and End Date/Time | MAY | [0..1] | DR Date/Time Range | |||||
8 | 01581 | Autopsy Performed By | MAY | [0..1] | XCN Extended Composite ID Number and Name for Persons | |||||
9 | 01582 | Coroner Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables |
Seq# | Data Element | Description | Flags | Implement | Cardinality | Length | C.LEN | Vocabulary | Data Type | |
---|---|---|---|---|---|---|---|---|---|---|
PDA | ||||||||||
1 | 01574 | Death Cause Code | MAY | [0..*] | CWE Coded with Exceptions | |||||
2 | 01575 | Death Location | MAY | [0..1] | PL Person Location | |||||
3 | 01576 | Death Certified Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | |||
4 | 01577 | Death Certificate Signed Date/Time | MAY | [0..1] | DTM Date/Time | |||||
5 | 01578 | Death Certified By | MAY | [0..1] | XCN Extended Composite ID Number and Name for Persons | |||||
6 | 01579 | Autopsy Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | |||
7 | 01580 | Autopsy Start and End Date/Time | MAY | [0..1] | DR Date/Time Range | |||||
8 | 01581 | Autopsy Performed By | MAY | [0..1] | XCN Extended Composite ID Number and Name for Persons | |||||
9 | 01582 | Coroner Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables |
Base Framework | Base Standard Profile | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Seq# | Data Element | Description | Flags | Implement | Cardinality | Length | C.LEN | Vocabulary | Data Type | Implement | Vocabulary | |
PDA | ||||||||||||
1 | 01574 | Death Cause Code | MAY | [0..*] | CWE Coded with Exceptions | MAY | ||||||
2 | 01575 | Death Location | MAY | [0..1] | PL Person Location | MAY | ||||||
3 | 01576 | Death Certified Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | MAY | ||||
4 | 01577 | Death Certificate Signed Date/Time | MAY | [0..1] | DTM Date/Time | MAY | ||||||
5 | 01578 | Death Certified By | MAY | [0..1] | XCN Extended Composite ID Number and Name for Persons | MAY | ||||||
6 | 01579 | Autopsy Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | MAY | ||||
7 | 01580 | Autopsy Start and End Date/Time | MAY | [0..1] | DR Date/Time Range | MAY | ||||||
8 | 01581 | Autopsy Performed By | MAY | [0..1] | XCN Extended Composite ID Number and Name for Persons | MAY | ||||||
9 | 01582 | Coroner Indicator | MAY | [0..1] | [1..1] | univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS) | ID Coded Value for HL7 Defined Tables | MAY |
Base Framework | Base Standard Profile | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Seq# | Data Element | Description | Flags | Optionality | Repetition | Length | C.LEN | Table | Data Type | Optionality | Table | |
PDA | ||||||||||||
1 | 01574 | Death Cause Code | O | Y | CWE Coded with Exceptions |
|||||||
2 | 01575 | Death Location | O | PL Person Location |
||||||||
3 | 01576 | Death Certified Indicator | O | [1..1] | ID Coded Value for HL7 Defined Tables |
(0136) | ||||||
4 | 01577 | Death Certificate Signed Date/Time | O | DTM Date/Time |
||||||||
5 | 01578 | Death Certified By | O | XCN Extended Composite ID Number and Name for Persons |
||||||||
6 | 01579 | Autopsy Indicator | O | [1..1] | ID Coded Value for HL7 Defined Tables |
(0136) | ||||||
7 | 01580 | Autopsy Start and End Date/Time | O | DR Date/Time Range |
||||||||
8 | 01581 | Autopsy Performed By | O | XCN Extended Composite ID Number and Name for Persons |
||||||||
9 | 01582 | Coroner Indicator | O | [1..1] | ID Coded Value for HL7 Defined Tables |
(0136) |
Seq# | Data Element | Description | Optionality | Repetition | Length | C.LEN | Table | Data Type | |
---|---|---|---|---|---|---|---|---|---|
PDA | |||||||||
1 | 01574 | Death Cause Code | O | Y | CWE Coded with Exceptions |
||||
2 | 01575 | Death Location | O | PL Person Location |
|||||
3 | 01576 | Death Certified Indicator | O | [1..1] | (0136) | ID Coded Value for HL7 Defined Tables |
|||
4 | 01577 | Death Certificate Signed Date/Time | O | DTM Date/Time |
|||||
5 | 01578 | Death Certified By | O | XCN Extended Composite ID Number and Name for Persons |
|||||
6 | 01579 | Autopsy Indicator | O | [1..1] | (0136) | ID Coded Value for HL7 Defined Tables |
|||
7 | 01580 | Autopsy Start and End Date/Time | O | DR Date/Time Range |
|||||
8 | 01581 | Autopsy Performed By | O | XCN Extended Composite ID Number and Name for Persons |
|||||
9 | 01582 | Coroner Indicator | O | [1..1] | (0136) | ID Coded Value for HL7 Defined Tables |
Definition: This field is valued with the reason of the death.
Definition: This field is valued with the place the death occurred.
Definition: This field indicates whether a death was officially certified or not. Refer to HL7 Table 0136 - Yes/No Indicator in Chapter 2C, Code Tables, for valid values.
Definition: This field is valued with the date and time the death certificate was signed.
Definition: This field is valued with the person who signed the death certificate.
Definition: This field indicates whether an autopsy was performed. Refer to HL7 Table 0136 - Yes/No Indicator in Chapter 2C, Code Tables, for valid values.
Definition: If an autopsy is performed, this field is valued with the date and time the autopsy was begun and completed
Definition: This field is valued with the authority who performed the autopsy.
Definition: This flag indicates whether the case/death has been assigned to the coroner/medical examiner for investigative purposed. Refer to HL7 Table 0136 - Yes/No Indicator in Chapter 2C, Code Tables, for valid values.