visit the hl7 website The Demo site for our new HL7 Version 2+ (plus) Standard

5.2.0.282 0357 - Message Error Condition Codes (2.C.2.282)

Concept Domain Information

Display Name: Message Error Condition Codes
Description:
Interpretation: Fehlerbeschreibung

Value Set Information

OID: 2.16.840.1.113883.21.233
Description: HL7 (communications) error codes, as transmitted in a message acknowledgement.
Symbolic Name: messageErrorCondition

Binding Information

Binding: universal

Table Metadata

Table: 357
Steward: InM

Code System Identification Information

CS-OID: 2.16.840.1.113883.18.217
Description: HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.
CS Symbolic Name: messageErrorCondition
case insensitive: Falsch
contains 'unknown': Falsch
contains 'other': Wahr

Code System Version Information

OID Version:
3

Table Values

Value Display Name Interpretation Comment Usage Note Modification Date Active
0 Message accepted Nachricht akzeptiert Success. Optional, as the AA conveys success. Used for systems that must always return a status code. Jul 13 2015  
100 Segment sequence error Fehler in der Segmentreihenfolge Error: The message segments were not in the proper order, or required segments are missing. Jul 13 2015  
101 Required field missing erforderliches Feld leer Error: A required field is missing from a segment Jul 13 2015  
102 Data type error Datentypfehler Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO". Jul 13 2015  
103 Table value not found fehlender Eintrag in der Tabelle Error: A field of data type ID or IS was compared against the corresponding table, and no match was found. Jul 13 2015  
104 Value too long Error: a value exceeded the normative length, or the length that the application is able to safely handle. Jul 13 2015  
198 Non-Conformant Cardinality Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message. Aug 25 2022  
199 Other HL7 Error Error Aug 25 2022  
200 Unsupported message type Nachrichtentyp wird nicht unterstützt Rejection: The Message Type is not supported. Jul 13 2015  
201 Unsupported event code Ereignis wird nicht unterstützt Rejection: The Event Code is not supported. Jul 13 2015  
202 Unsupported processing id Processing-ID wird nicht unterstützt Rejection: The Processing ID is not supported. Jul 13 2015  
203 Unsupported version id Version wird nicht unterstützt Rejection: The Version ID is not supported. Jul 13 2015  
204 Unknown key identifier Schlüsselwert nicht gefunden ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code). Jul 16 2017  
205 Duplicate key identifier doppelter Schlüsselwert ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code). Jul 16 2017  
206 Application record locked Datensatz durch Applikation gesperrt ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code). Jul 16 2017  
207 Application error applikationsinterner Fehler This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide. Jul 25 2017