5.2.0.732 0914 - Root Cause (2.C.2.732)

Concept Domain Information

Display Name: Root Cause
Description:
Interpretation:

Value Set Information

OID: 2.16.840.1.113883.21.439
Description: Value Set of codes specifying a root cause.
Symbolic Name: rootCause

Binding Information

Binding: example

Table Metadata

Table: 914
Steward: OO

Code System Identification Information

CS-OID: 2.16.840.1.113883.18.421
Description: Code system of concepts specifying the root cause. Used in HL7 Version 2.x messaging in the OBX segment.
CS Symbolic Name: rootCause
case insensitive: Falsch
contains 'unknown': Falsch
contains 'other': Falsch

Code System Version Information

OID Version:
1

Table Values

Value Display Name Interpretation Comment Usage Note Modification Date Active
AP Analysis Process Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure Jul 13 2015  
IM Information Management Enter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • Other Enter (IM) when INFORMATION MANAGEMENT is the reason due to: • Database or Programming issues • Overriding of test results • Inaccurate calculations • Inaccurate flagging, reference ranges, units of measure • Incomplete/inaccurate transmission of test results • Other Jul 13 2015  
L Laboratory Enter (L) when LABORATORY is the reason due to:

• Data Entry error

• Testing/Technical error

• Repeat testing causing change to test result

Enter (L) when LABORATORY is the reason due to: • Data Entry error • Testing/Technical error • Repeat testing causing change to test result Jul 13 2015  
NA Not Applicable Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision) Enter (NA) when NOT-APPLICABLE is the reason due to: • If no revisions performed or • unable to determine reason for revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a correction (revision) Jul 13 2015  
PD Placer Data Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...) Enter (PD) when new or changed PLACER DATA information is the reason due to: • Changed patient demographics or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...) Jul 13 2015