HL7 - Version 2.4


Table 0472: TQ Conjunction ID

Interpretation: TQ Verknüpfung
OID Table: 2.16.840.1.113883.12.472
Codesystem OID: 2.16.840.1.113883.18.300 Version 1
Value Set OID: 2.16.840.1.113883.21.316
Binding: universal
Expansion: all codes from codesystem
Vocabulary Domain: tbd
Table Type: HL7
Case insensitive: Falsch
Section 4

Value Description German Interpretation Comment Chapter
S Synchronous. Do the next specification after this one (unless otherwise constrained by the following components: ORC-7^4-start date/time and ORC-7^5-end date/time). An "S" specification implies that the second timing sequence follows the first, e.g., when

4
A Asynchronous: Do the next specification in parallel with this one (unless otherwise constrained by the following components: ORC-7^4-start date/time and ORC-7^5-end date/time). The conjunction of "A" specifies two parallel instructions, as are sometimes

4
C This is an actuation time. It will be followed by a completion time for the service. This code allows one to distinguish between the time and priority at which a service should be actuated (e.g., blood should be drawn) and the time and priority at which

4

Comments made by the German HL7 User Group:

TQ Verknüpfung

Used Within the following Components

71 conjunction component (Verknüpfung)