v2+ Vocabulary
0.3.0 - Working Draft to present the concept ideas (FO)

v2+ Vocabulary - Local Development build (v0.3.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: Abnormal Flags (2.2 - 1.1.0) (Experimental)

Official URL: http://terminology.hl7.org/v2plusvocab/ValueSet/hl7VSinterpretationCodeV110 Version: 1.1.0
Active as of 2025-08-05 Computable Name: Hl7VSinterpretationCodeV110
Other Identifiers: OID:2.16.840.1.113883.1.11.78

Copyright/Legal: HL7 Inc., 2024

A categorical assessment, providing a rough qualitative interpretation of the observation value, such as “normal”/ “abnormal”,”low” / “high”, “better” / “worse”, “susceptible” / “resistant”, “expected”/ “not expected”. The value set is intended to be for ANY use where coded representation of an interpretation is needed. Notes: This is being communicated in v2.x in OBX-8, in v3 in ObservationInterpretation (CWE) in R1 (Representative Realm) and in FHIR Observation.interpretation. Historically these values come from the laboratory domain, and these codes are extensively used. The value set binding is extensible, so codes outside the value set that are needed for interpretation concepts (i.e. particular meanings) that are not included in the value set can be used, and these new codes may also be added to the value set and published in a future version.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

Expansion performed internally based on codesystem Abnormal Flags (2.2 - 1.1.0) v1.1.0 (CodeSystem)

This value set contains 19 concepts

CodeSystemDisplay (en-US)Definition
  <http://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Below absolute low-off instrument scaleBelow absolute low-off instrument scale
  >http://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Above absolute high-off instrument scaleAbove absolute high-off instrument scale
  Ahttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Abnormal (applies to non-numeric results)Abnormal (applies to non-numeric results)
  AAhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Very abnormalVery abnormal (applies to non-numeric units, analogous to panic limits for numerics limits)
  Bhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110BetterBetter (use when direction not relevant)
  Dhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Significant change downSignificant change down
  Hhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Above high normalAbove high normal
  HHhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Above upper panic limitsAbove upper panic limits
  Ihttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110IntermediateIntermediate
  Lhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Below low normalBelow low normal
  LLhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Below lower panic limitsBelow lower panic limits
  MShttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Moderately sensitiveModerately sensitive
  Nhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110NormalNormal (applies to non-numeric results)
  Rhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110ResistantResistant
  Shttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110SensitiveSensitive
  Uhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Significant change upSignificant change up
  VShttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110Very sensitiveVery sensitive
  Whttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110WorseWorse (use when direction not relevant)
  nullhttp://terminology.hl7.org/v2plusvocab/CodeSystem/observationInterpretationV110No range defined, or normal ranges don't applyNo range defined, or normal ranges don't apply

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code